Product Details:
Minimum Order Quantity | 01 Unit |
Pressure Range (hpa) | 4 - 25 cmH20 |
Ramp Time (min.) | 10 minutes |
Brand | Nidek Medical |
Model | Breathe Smart 20 |
Display (inch) | 3 '' colour Display |
Driven Type | German Blower |
Portable | Yes |
Data Storage | yes |
Epap Range | 4 - 20 cmH20 |
Type | Auto,Manual |
Weight (kg) | 1 kg |
Warranty | 2 years |
Starting Ramp Pressure | 4 cmH20 |
Ipap Range | 4 - 20 cmH20 |
Color | Black |
Condition | New |
Application | Hospital |
DPAP provides effective bi-level positive airway pressure treatment for a variety of respiratory conditions including Obstructive Sleep Apnea (OSA).
A Bi-level device is ideal for the treatment of tubercular and non-tubercular lung diseases. There are significant numbers of Chronic Obstructive Pulmonary Disease (COPD) cases that require basic ventilation support. In such cases, Bi-level support without the complications of invasive ventilation proves to be very effective. Bi-level can also be effective in case of Acute Respiratory Distress Syndrome (ARDS) and asthma.
DPAP Machines : Product specifications
Model ParametersDPAP20DPAP20PlusDPAP25PlusDPAP 30 ProModeCPAP, SCPAP, S, S/T, TCPAP, S, S/T, TCPAP, S, S/T, T, PCIPAP range4 – 20cmH2O4 – 20cmH2O4 – 25cmH2O4 – 30cmH2O
EPAP range4 – 20cmH2O4 – 20cmH2O4 – 20cmH2O4 – 20cmH2OCPAP range4 – 20cmH2O4 – 20cmH2O4 – 20cmH2O4 – 20cmH2OE-triggerAuto,1 to 3Auto,1 to 3Auto,1 to 6Rise TimeAuto,1 to 3Auto,1 to 3Auto,1 to 6IPAP Rise Time100-600 msec100-600 msec100-600 msec100-600 msecBreath rate (BPM)Adjustable 0 – 40Adjustable 0 – 40Adjustable 0 – 40Noise Level (dBA)Less than 30dB@ 10cmH2OLess than 30dB@ 10cmH2OLess than 30dB@ 10cmH2OLess than 30dBA 10cmH2OCPAP Ramp
(minutes)0 – 60minutes
1 minute increment0 – 60minutes
1 minute increment0 – 60minutes
1 minute increment0 – 60minutes. 1 minute increment
Display DataIPAP, EPAP,
Vt, Vleak, BRIPAP, EPAP,
Vt, VleakIPAP, EPAP
Vt, Vleak,IPAP, EPAP, Vt, Vleak,AlarmsPower failure
Mask AlarmPower failure
Mask Alarm
Apnea Alarm
High/Low Rate AlarmPower failure
Mask Alarm,
Apnea Alarm
High/Low Rate AlarmPower failure, Mask off, Apnea, High / Low Rate, Motor failure, Low Minute Ventilation, Motor failureScreens2.8″ TFT2.8″ TFT2.8″ TFT2.8″ TFTDisplaysPressure bar graph/DataPressure bar graph/DataPressure bar graph/DataPressure bar graph, Data,
Waveform (Pressure, Flow Volume Curve)Tube Length1.8m, 2m1.8m, 2m1.8m, 2m1.8m, 2mDimensions (L*W*H)21X21X11cm21X21X11cm21X21X11cm21X21X11cmWeight (kg)2.12.12.12.1Heated HumidifierOptionalOptionalOptionalOptionalMemoryMicro SD CardMicro SD CardMicro SD CardMicro SD CardWarranty2 Years2 Years2 Years2 Years
Additional Information: